ASSA ABLOY, the global leader in door opening solutionsInstallation & Programming GuideEMTouch™ & EMTouch™ Classic StyleElectronic Lever Locks
10In order to perform each of the following six functions, the lock must rst be placed in Programming Mode:*If no input within 20 seconds, Yellow LED
11IN8-EMTOUCHLL 06/24/2013Restoring the Lock to Factory Default Setting• Press and hold EMTEK button for 3 seconds.• Enter “000000”• After 2 beeps
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.Copyright © 201
2ITEM NO. DESCRIPTION QTY.1 Key 22 Outside Trim Plate Assembly 13 Adjustable Latch for 2 3/8” or 2 ¾” Backset 14 Inside Trim Plate Assembly 1
32 3/8” or 2 ¾” Backset2 1/8” Dia Bore1/8” Deep2 ¼”1 “1” Diameter Edge Bore2. Door Prep 3. Door Jamb Prep1. Conrm HandingHANDING OF DOOR IS ALWAYS D
4Use a Phillips head screwdriver to remove screws (item #4c) shown below and detach Inside Trim Plate from the Inside Chassis.Fasten Adjustable Latch
53. Install Outside Trim Plate AssemblyStep 1: While holding Outside Trim Plate Assembly, Press the Plastic Extender (A) into end of Spindle Shaft (B)
64. Install Inside ChassisCAM LINK MUST REMAIN IN THE CORRECT POSITION DURING INSTALLATION.!Step 1: Confirm the position of Cam Link.For Left Hand Loc
7CHECK ALIGNMENT BEFORE FULLY TIGHTENING SCREWS.!Step 4: Connect Wire Harness (A) and tuck Connectors as shown (B).ABStep 5: Install Battery.For op
85. Install Inside Trim PlateScrews (item #4c)Fasten Inside Trim Plate using two #8-32 x 3/8” Flat Head Machine Screws (item #4c). *Neutral position
9Your Emtek lock is shipped with two 4-digit user codes and a 6-digit programming code. These codes are randomly generated at the factory. (Turn to ne